Описание

  • Auxiliary release on the front
  • Without door monitoring contact
  • Increased horizontal overtravel
Approach direction Horizontal and vertical Can be adjusted in 90° steps Increased overtravel for horizontal approach direction Solenoid operating voltage
  • AC 110 V +10%, -15%
Guard locking type
TP1Closed-circuit current principle, guard locking by spring force. Release by applying voltage to the guard locking solenoid.
Switching element
528Slow-action switching contact 1 NC + 1 NO
Auxiliary releaseIs used for releasing the guard locking with the aid of a tool. To protect against tampering, the auxiliary release is sealed with sealing lacquer.
Housing material Reinforced thermoplastic
Weight
Net 0,5 kg
Ambient temperature -20 ... 55 °C
Degree of protection IP67
Mechanical life 1 x 106
Contact material Silver alloy, gold flashed
Switching principle Slow-action switching contact
Installation orientation Any
Number of door position positively driven contacts 1
Number of NO contacts 1
Connection
3 x M20 x 1.5
Approach speed
max. 20 m/min
Actuation frequency 1200 1/h
Guard locking principle Closed-circuit current principle
Locking force Fmax 1300 N
Locking force FZh 1000 N
Retention force 10 N
Extraction force 20 N
Actuating force 10 N
Electrical connection ratings
Thermal rated current Ith 4 A
Utilization category according to EN 60947-5-1
AC-15 4A 230V
DC-13 4A 24V
Solenoid operating voltage
AC 110 V -15% ... +10%
Short circuit protection according to IEC 60269-1
(Fuse) 4A gG
Rated insulation voltage Ui 250 V
Rated impulse withstand voltage Uimp 2,5 kV
Switching voltage
Min. at 10mA 12 V
Switching current
Min. at 24V 1 mA
Power consumption 10 W
Solenoid duty cycle 100 %
Connection cross-section 0,34 ... 1,5 mm?
Reliability values according to EN ISO 13849-1
Monitoring of guard locking and the safety guard position
B10D 3 x 106
Control of the guard locking
Category Depending on external control of guard locking
Performance Level Depending on external control of guard locking
PFHD Depending on external control of guard locking
In combination with Actuator BETAETIGER-P-GTMechanical values and environment
Overtravel A B C D E 2 mm
Overtravel K L M N 1,5 mm
In combination with Actuator BETAETIGER-P-GNTMechanical values and environment
Overtravel A B C D E 7 mm
''